Search results for "Eye examination"

showing 10 items of 13 documents

Symptomatic accommodative and binocular dysfunctions from the use of flat-panel displays

2018

AIM: To determine the presence of symptomatic accommodative and non-strabismic binocular dysfunctions (ANSBD) in a non-presbyopic population of video display unit (VDU) users with flat-panel displays. METHODS: One hundred and one VDU users, aged between 20 to 34y, initially participated in the study. This study excluded contact-lens wearers and subjects who had undergone refractive surgery or had any systemic or ocular disease. First, subjects were asked about the type and nature of eye symptoms they experienced during VDU use. Then, a thorough eye examination excluded those subjects with a significant uncorrected refractive error or other problem, such as ocular motility disorders, vertica…

0301 basic medicinenon-strabismic binocular dysfunctionsUlls Acomodació i refraccióRefractive errormedicine.medical_specialtyConvergence insufficiencygenetic structuresAccommodative insufficiencymedicine.medical_treatmentaccommodative dysfunctionsPopulationAudiologyOptometria03 medical and health sciences0302 clinical medicinelcsh:OphthalmologyRefractive surgerygeneral binocular dysfunctionsmedicineeducationInvestigationeye symptomseducation.field_of_studymedicine.diagnostic_testbusiness.industryFusional vergencemedicine.diseaseeye diseasesOphthalmology030104 developmental biologyEye examinationlcsh:RE1-994030220 oncology & carcinogenesis505video display unitbusinessBinocular vision
researchProduct

Corneoscleral contact lenses for visual rehabilitation after keratoplasty surgery.

2019

Abstract Purpose To report the use of corneoscleral lenses (CSL) in keratoconus patients who were unsatisfied with their visual outcomes after keratoplasty surgery. Methods Eleven consecutive cases with unsatisfactory vision with spectacles, due to irregular astigmatism, preferred to try CSL before SL due to handling or economic issues. An eye examination included refraction and visual acuity assessment, anterior eye biomicroscopy, ocular fundus examination, corneal topographic analysis, endothelial-cell count (ECC) and evaluation of corneal biomechanical parameters (corneal resistance factor, CRF; corneal hysteresis, CH; corneal-compensated intraocular pressure, IOPcc). The fitting process…

AdultMaleKeratoconusIntraocular pressuremedicine.medical_specialtyVisual acuitygenetic structuresContact LensesVisual rehabilitationKeratoconusRefraction Ocularlaw.inventionCorneal hysteresisCorneal Transplantation03 medical and health sciences0302 clinical medicinelawmedicineHumansAgedRetrospective StudiesAged 80 and overKeratometerIrregular astigmatismmedicine.diagnostic_testbusiness.industryAstigmatismCorneal TopographyGeneral MedicineMiddle Agedmedicine.diseaseeye diseasesSurgeryOphthalmologyEye examination030221 ophthalmology & optometryFemalesense organsmedicine.symptombusiness030217 neurology & neurosurgeryKeratoplasty PenetratingOptometryContact lensanterior eye : the journal of the British Contact Lens Association
researchProduct

Risk factors for high myopia: a 22‐year follow‐up study from childhood to adulthood

2018

PURPOSE To determine the effect of the definition of high myopia on its prevalence and risk factors for high myopia. METHODS A total of 240 myopic schoolchildren (119 boys and 121 girls) at the mean age of 10.9 years (range 8.8-12.8 years) were recruited to a randomized clinical trial of myopia treatment among children from 3rd- and 5th grades of school referred for an eye examination due to poor distant vision and having no previous spectacles. Clinical follow-ups, including refraction with cycloplegia, were conducted annually at 3 years [third follow-up here = clinical follow-up 1, (n = 237)], and thereafter twice at approximately 10-year intervals [clinical follow-ups 2 (n = 179) and 3, …

AdultMalePediatricsmedicine.medical_specialtyYounger ageAdolescentgenetic structuresRefraction Ocularlaw.inventionYoung Adult03 medical and health sciences0302 clinical medicineRandomized controlled trialRisk FactorslawSurveys and QuestionnairesMyopiaPrevalencemedicineHumansChildFinlandRetrospective Studiesmedicine.diagnostic_testbusiness.industryVision TestsFollow up studiesHigh myopiaCycloplegiaGeneral MedicineOdds ratioeye diseasesOphthalmologyEyeglassesEye examinationCohortDisease Progression030221 ophthalmology & optometryFemalesense organsmedicine.symptombusiness030217 neurology & neurosurgeryFollow-Up StudiesForecastingActa Ophthalmologica
researchProduct

Visual quality with corneo-scleral contact lenses for keratoconus management

2018

Purpose: To assess the visual quality achieved by fitting corneo-scleral contact lenses (CScL) for keratoconus management. Methods: Thirty patients with keratoconus presented to have CScL fitted because of the unsatisfactory visual quality they experienced with their contact lenses or spectacles. The eye examination included visual acuity assessment, anterior eye biomicroscopy, ocular fundus examination, corneal topographic analysis, endothelialcell count, contrast sensitivity and aberrometry. The fitting process was performed using a diagnostic trial set. Subjective visual quality and comfort, and contact lens wear time were also reported. Patients were monitored for one year. Results: Thr…

Keratoconusmedicine.medical_specialtyVisual acuityCorneal ectasiagenetic structuresmedia_common.quotation_subjectKeratoconus03 medical and health sciences0302 clinical medicineOphthalmologyAberrometrymedicineContrast (vision)In patientmedia_commonmedicine.diagnostic_testbusiness.industryMean ageCorneoscleral contact lensGeneral Medicinemedicine.diseaseeye diseasesContact lensOphthalmologyEye examination030221 ophthalmology & optometrysense organsmedicine.symptombusiness030217 neurology & neurosurgeryOptometry
researchProduct

Genetic systems for a new approach to risk of progression of diabetic retinopathy.

2016

OBJECTIVE: To evaluate the risk of progression of diabetic retinopathy (DR) using new strategies to obtain genetic information in type 2 diabetes (T2D) based on interfering ribonucleic acid (RNA). MATERIAL AND METHODS: A prospective multicentre case-control study of 132 participants was distributed into: T2D with (+DR) or without (-DR) (T2DG; n=77), and a control group (CG; n=55). After an eye examination and personal interview, tears were collected for molecular analysis (expression of microRNAs [miRNAs] (miRCURY ARN Isolation Kit, Qiagen)]. Libraries, 137 vs. 140bp (GeneMapper, Applied Biosystems), were obtained in 18 samples (T2DG+DR=6; T2DG-DR=6; CG=6) by performing next-generation sequ…

Male0301 basic medicineOncologyMicro RNAsmedicine.medical_specialtyBiomarcadores preclinicosType 2 diabetesMicro-ARNBioinformaticsRisk AssessmentInterference by RNA03 medical and health sciencesDiabetic retinopathyInternal medicineType 2 diabetes mellitusmedicineHumansProspective StudiesFamily historyAgedDiabetic Retinopathymedicine.diagnostic_testSequence Analysis RNAbusiness.industryPre-clinical biomarkersType 2 Diabetes MellitusGenetic systemsRetinopatia diabeticaGeneral MedicineDiabetic retinopathyMiddle Agedmedicine.diseaseInterferencia por ARNMolecular analysisDiabetes mellitus tipo 2030104 developmental biologyDiabetes Mellitus Type 2Eye examinationCase-Control StudiesDisease ProgressionTearsFemalebusinessBiomarcadores preclínicos Diabetes mellitus tipo 2 Diabetic retinopathy Interference by RNA Interferencia por ARN Micro RNAs Micro-ARN Pre-clinical biomarkers Retinopatía diabética Type 2 diabetes mellitus
researchProduct

Visual quality with corneo-scleral contact lenses after intracorneal ring segment (ICRS) implantation for keratoconus management

2019

Purpose: To evaluate the visual quality results when fitting a corneo-scleral contact lens (CScL) after intracorneal ring segment (ICRS) implantation for keratoconus management. Methods: Twenty-seven eyes of 27 patients with keratoconus underwent ICRS implantation and had CScL fitted as their visual quality was unsatisfactory with their spectacles or contact lenses. Patients received a complete eye examination, refraction and visual acuity assessment, anterior eye biomicroscopy, ocular fundus examination, corneal topographic analysis, endothelial-cell count, and visual quality assessment using contrast sensitivity and aberrometry tests. A diagnostic trial set was used in the fitting process…

MaleCorneal Wavefront AberrationVisual acuitygenetic structuresVisual Acuity0302 clinical medicineIntracorneal ring segmentProsthesis FittingContrast (vision)media_commonmedicine.diagnostic_testQuality assessmentCorneoscleral contact lensProstheses and ImplantsGeneral MedicineMiddle AgedRefractive ErrorsEye examinationFemalemedicine.symptomScleraAdultmedicine.medical_specialtyKeratoconusCorneal ectasiaContact LensesCorneal Stromamedia_common.quotation_subjectKeratoconusContrast SensitivityProsthesis ImplantationYoung Adult03 medical and health sciencesOphthalmologyAberrometrymedicineHumansIntracorneal ring segmentbusiness.industryAberrometryCorneal Topographymedicine.diseaseeye diseasesContact lensOphthalmology030221 ophthalmology & optometrysense organsbusiness030217 neurology & neurosurgeryOptometryContact Lens and Anterior Eye
researchProduct

Corneo-scleral contact lenses in an uncommon case of keratoconus with high hyperopia and astigmatism

2017

Purpose: To analyse the visual quality achieved by fitting corneo-scleral contact lenses (CScL) in an uncommon case of bilateral keratoconus, high hyperopia and astigmatism. Methods: A 45-year-old man presented for eye examination due to the unsatisfactory quality of his vision wearing soft toric contact lenses. He presented high hyperopia and astigmatism with bilateral keratoconus. He was fitted with CScL to correct his irregular astigmatism and ocular aberrations. A diagnostic trial set was used in the fitting process and he was assessed according to standardised fitting methodology. Visual acuity, corneal topography, biometry and ocular aberrations were evaluated. The follow-up period wa…

Malemedicine.medical_specialtyKeratoconusCorneal Wavefront AberrationVisual acuityCorneal ectasiagenetic structuresContact LensesVisual AcuityAstigmatismKeratoconusCornea03 medical and health sciences0302 clinical medicineProsthesis FittingOphthalmologyCorneamedicineHumansHigh orderIrregular astigmatismmedicine.diagnostic_testbusiness.industryAstigmatismCorneal TopographyEye Diseases HereditaryCorneoscleral contact lensGeneral MedicineMiddle Agedmedicine.diseaseCorneal topographyeye diseasesOphthalmologyHyperopiamedicine.anatomical_structureEye examination030221 ophthalmology & optometrysense organsmedicine.symptombusinessSclera030217 neurology & neurosurgeryOptometry
researchProduct

Prevalence of early and late age-related macular degeneration in India: the INDEYE study.

2010

Purpose.: To estimate the prevalence of early and late age-related macular degeneration (AMD) in India. Methods.: Of 7518 people aged 60 years and older identified from randomly sampled villages in North and South India, 5853 (78%) attended an eye examination including fundus photography. Fundus images were graded according to the Wisconsin Age-Related Maculopathy Grading System. Results.: Fundus images were ungradable in 1587 people, mainly because of cataract. People 80 years of age and older were less likely to attend the eye examination and more likely to have ungradable images. For ages 60 to 79 years, the percent prevalence (95% confidence interval [CI]) were late AMD 1.2 (0.8–1.5); a…

Rural Populationmedicine.medical_specialtyUrban Populationgenetic structuresVisual AcuityPrevalenceIndiaDiagnostic Techniques OphthalmologicalDrusenFundus (eye)Macular DegenerationAge DistributionOphthalmologyEpidemiologyPrevalencemedicineHumansSex DistributionAgedAged 80 and overmedicine.diagnostic_testbusiness.industryFundus photographyArticlesMiddle AgedMacular degenerationmedicine.diseaseeye diseasesEye examinationMaculopathysense organsbusiness
researchProduct

<title>The perception of isoluminant coloured stimuli of amblyopic eye and defocused eye</title>

2008

In routine eye examination the visual acuity usually is determined using standard charts with black letters on a white background, however contrast and colour are important characteristics of visual perception. The purpose of research was to study the perception of isoluminant coloured stimuli in the cases of true and simulated amlyopia. We estimated difference in visual acuity with isoluminant coloured stimuli comparing to that for high contrast black-white stimuli for true amblyopia and simulated amblyopia. Tests were generated on computer screen. Visual acuity was detected using different charts in two ways: standard achromatic stimuli (black symbols on a white background) and isoluminan…

Visual acuityVisual perceptiongenetic structuresmedia_common.quotation_subjectLuminanceeye diseaseslaw.inventionAchromatic lenslawPerceptionmedicineContrast (vision)Optometrymedicine.symptomColour contrastRoutine eye examinationPsychologymedia_commonSPIE Proceedings
researchProduct

Prevalence of visual impairment and refractive errors in an urban area of Mexico

2019

AIM: To determine the distribution of refractive errors in a school-age population in Quintana Roo (Mexico) in the framework of an international cooperation campaign for the prevention of blindness. METHODS: A sample of 2647 school-age children (ranging from 5 to 14 years old) with a mean age of 9.1±1.9 years old were tested by trained volunteers for distance visual acuity (VA) and refractive errors. The first screening examination included uncorrected distance visual acuity (UDVA) and VA with a +2.00 D lens. Inclusion criteria for a second complete cycloplegic eye examination performed by an optometrist were UDVA <20/25 (0.10 logMAR or 0.8 decimal) and/or VA with +2.00 D ≥20/25. RESULTS: A…

hyperopiaRefractive errormedicine.medical_specialtyBilateral amblyopiaDistance visual acuitygenetic structuresPopulationVisual impairmentvisual impairmentBlindnessScreening Examination03 medical and health sciences0302 clinical medicinelcsh:OphthalmologyOphthalmologyMyopiaMedicinemyopiarefractive erroreducationÓpticaInvestigationeducation.field_of_studyBlindnessmedicine.diagnostic_testbusiness.industryRefractive errorVisual impairmentmedicine.diseaseeye diseasesOphthalmologyHyperopialcsh:RE1-994Eye examination030221 ophthalmology & optometrysense organsmedicine.symptombusinessblindness
researchProduct